Logo Airex Control

SCR/SSR

Simple phase

Zero crossing

Image of 7100L Image of 7100S Image of TE10S

7100L

  • 16-100 amps, 120-600Vac
  • Fixed build design
  • Zero cross fired
  • LED status indicator

Specifications

7100S

  • 16-250 Amps
  • Voltages up to 500 Vac
  • On-Off Logic or Fast Cycle Firing
  • Suitable for SWIR or Resistive Loads
  • Load Diagnostics and Fault Indication
  • Optional Modbus® RTU Communications

Specifications

TE10S

  • Robust mechanical design
  • 16–50 amps, 240–500Vac max.
  • 1ø zero crossing fired
  • LED status indicator
  • Optional partial load fail
  • Optional load current monitor and diagnostics

Specifications

Phase angle

Image of TE10S Image of 7100A Image of TE10P

TE10A

  • Robust mechanical design
  • 16–50 amps, 240–500Vac max.
  • 1ø zero crossing fired or phase angle fired
  • LED status indicator
  • Optional current limit

Specifications

7100A

  • 16-250 amps, 100-500 Vac
  • Zero cross or phase angle firing
  • Optional current limit

Specifications

TE10P

  • 16A-400A, 500Vac max.
  • Suitable for resistive, inductive or temperature and time dependent loads
  • Accuracy and stability better than 1%
  • Optional Modbus® and Profibus® comms.
  • Analog retransmission and alarms
  • Optional model 260 diagnostic unit

Specifications

Three Phase

Image of 7300A Image of TE300 Image of 7300S

7300A

  • 16-40 amps, 200-500 Vac
  • Zero cross or phase angle firing
  • Optional current limit
  • Optional Load Fault Alarms

Specifications

TE300

  • 16–63 amps, 500Vac max.
  • 3ø, three, four and six-wire loads (three leg switching)
  • Advanced firing modes
  • LED status indicator

Specifications

7300S

  • Current range; from 16 to 160 amps at 45°C
  • Voltage up 500V
  • Inputs: Logic (AC or DC) or Analogue 4-20mA which gives time proportional output
  • Suitable for SWIR or resistive loads
  • Overtemperature shutdown for fan cooled units (over 100 amps)
  • Options include: Thyristor short circuit alarm Overtemperature alarm Diagnostic load failure detection

Specifications

Image of TC3000 Image of TC3001

TC3000

  • 25-500 amps, 500Vac max
  • Three or four wire loads
  • Selectable control and firing modes
  • Resistive and inductive loads

Specifications

TC3001

  • 25-500 amps, 500Vac max
  • Three or four wire loads
  • Selectable control and firing modes
  • Resistive and inductive loads
  • Optional digital communications

Specifications

SSR

Image of RSxA Image of RVx3 Image of RVMA

RS Series

  • 50, 75 and 100 Amps, 660Vac max.
  • Single Phase Zero Cross Fired
  • Integral heatsink design
  • LED input and fault indicators
  • Internal I2t fusing
  • DC and AC Logic Inputs

Specifications

RVx3

  • 25 amps, 660Vac max.
  • Three phase (three leg) control
  • Zero switching
  • Suitable for resistive loads
  • Finger safe
  • LED status indicator

Specifications

RVMA

  • Integrated heatsink
  • Mounts on DIN rail or panel
  • Optically isolated
  • L.E.D. indicator
  • Built-in snubber
  • 4000 volt isolation
  • Zero voltage turn-on
  • Direct copper bonded SCRs
  • Oversized SCRs with:
  • 1400 blocking volt (6V)
  • 1000 V/µs immunity

Specifications